MS2900 SeriesMS2910
Chassis Mount Type
Potentiometer Transmitter
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
30,000Yen |
6Days
|
3Years |
-
-
|
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB |
Chassis Mount Type
CT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
3Years |
-
-
|
Input0 to 1A AC, 0 to 5A AC Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeDependent on the set value. |
Chassis Mount Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
3Years |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 250V AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeDependent on the set value. |
Chassis Mount Type
CT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
|
33,000Yen |
14Days
|
7Years |
-
RoHS10
|
Input0~1A AC 0~5A AC Output 11~5V Response Time400ms max. |
Chassis Mount Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
|
33,000Yen |
14Days
|
7Years |
-
RoHS10
|
Input0~ 110V AC 0~ 150V AC 0~ 300V AC Output 11~5V Response Time400ms max. |
Rack Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like, amplifies the millivolt input signals, and converts them into two mutually isolated DC output signals. Successor model: MS3706 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. Successor model: MS3710 or MS4110 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
CT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. Successor model: MS3720 or MS4120 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 70ms (0 to 63%) |
Rack Mount Type
PT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. Successor model: MS3721 or MS4121 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 70ms (0 to 63%) |
Rack Mount Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. |
|
55,000Yen / 75,000Yen |
45Days
|
3Years |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Plug-in Type
Synchro/Analog Converter
Converts synchro transmitter inputs into DC output signals. |
|
|
Please contact us
|
Please contact us |
-
RoHS6
|
InputSynchro 3-wire signal Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others |
Chassis Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
|
|
Please contact us
|
Please contact us |
-
-
|
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, +/-10V Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
|
|
Please contact us
|
Please contact us |
-
-
|
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Chassis Mount Type
CT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 70ms (0 to 60%) |
Chassis Mount Type
PT Transmitter (Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 250V AC, and others Output 11 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 70ms (0 to 60%) |
Unit Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. |
|
61,000Yen |
45Days
|
3Years |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer. Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
CT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |
Unit Type
PT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
|
55,000Yen |
45Days
|
3Years |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |
Unit Type
RTD Differential Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. |
|
61,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like, amplifies the millivolt input signals, and converts them into DC output signals. Successor model: MS3706 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into DC output signals. Successor model: MS3710 or MS4110 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Plug-in Type
Potentiometer Transmitter
Successor model: MS5310 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
CT Transmitter (Rms Calculation)
Successor model: MS5320 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
PT Transmitter (Rms Calculation)
Successor model: MS5321 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
Accelerometer Transmitter
No successor model. |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
Strain Gauge Transmitter
Successor model: MS5506 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
Potentiometer Transmitter
Successor model: MS5510 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
CT Transmitter (Rms Calculation)
Successor model: MS5320 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
PT Transmitter (Rms Calculation)
Successor model: MS5521 |
|
|
Please contact us
|
3Years |
-
-
|
|