MS3900 SeriesMP3900
Chassis Mount Type
Connector Cover
Chassis Mount Type
Connector Cover
Non-functional module used to fill empty slots in the chassis |
|
1,000Yen |
6Days
|
7Years |
-
RoHS10
|
|
Chassis Mount Type
Non-Conditioning I/O Adapter
I/O adapter that does not provide any signal conditioning. The front-accessible switch turns on or off the internal 250Ω shunt resistor. |
15,000Yen |
6Days
|
7Years |
-
RoHS10
|
InputDC current signal Output1DC voltage signal Output2DC voltage signal |
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC24V Supplied from a dedicated base |
InputThermocouple types: Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time160ms max. |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
InputRTD:Pt 100Ω、JPt 100Ω Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
Chassis Mount Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
25,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 10mV, 0 to 100mV, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time160ms max. |
Chassis Mount Type
High-Level Signal Conditioner
(Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA, 1 to 5V, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time85ms max. |
Chassis Mount Type
High-Level Signal Conditioner
(High Response Model)
Converts DC current or voltage signals into commonly used DC signals. |
25,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input1 to 5mA 10 to 50mA Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, |
Chassis Mount Type
Alarm Setter
Compares the levels of DC current or voltage signals with one set-point and outputs two independent isolated relay contact closure signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA 0 to 20mA Output 1,2Relay contact output (SPST independent single circuit) Operation settingBy front rotary switch Response Time150ms max. |
Chassis Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time180ms max. |
Chassis Mount Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
25,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA from 2-wire transmitters Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time85ms max. |
Chassis Mount Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputOpen collector, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response TimeDependent on input frequency. |
Chassis Mount Type
Pulse Shaper (Pulse Isolator)
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputOpen collector, Output 1TTL, Output 2TTL, Response TimeDependent on input frequency. |
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
Chassis Mount Type
First-Order Delay Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA Output 11 to 5V, Output 21 to 5V, 0 to 5V, Response TimeDependent on the set value. |
Chassis Mount Type
Filter Unit
Filters input signals with preset low-pass filter characteristics. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input+/-10V range Output+/-10V range Filter characteristics2nd order filter |
Chassis Mount Type
CT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 1A AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
Chassis Mount Type
PT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 100V AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
Chassis Mount Type
Analog/Frequency Converter
Converts DC current or voltage signals into pulse train signals. |
35,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA 0 to 20mA Output 1TTL, Output 2TTL, Response TimeDependent on input frequency. |
Chassis Mount Type
High-Level Signal Conditioner
(Fast Response Model)
Converts DC current or voltage signals into pulse train signals. |
30,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA (Input resistance 50Ω) Output1 to 5V, 0 to 5V, Response frequency10KHz-3dB |
Chassis Mount Type
High-Level Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA 0 to 20mA Output1 to 5V, 0 to 5V, Response Time15ms max. |
Chassis Mount Type
High-Level Signal Conditioner
(High Current Load Model)
Converts DC current or voltage signals into commonly used DC signals. |
20,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA, 1 to 5V, Output4 to 20mA, Response Time15ms max. |
Chassis Mount Type
Programmable Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
45,000Yen |
8Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputThermocouple types: Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response Time260ms max. |
Chassis Mount Type
Programmable RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
45,000Yen |
8Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputRTD: Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response Time260ms max. |
Chassis Mount Type
Programmable Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
45,000Yen |
8Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputInput span: 5mV to 2V Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response Time260ms max. |
Chassis Mount Type
Rack
For 4ch
Chassis for the MS3900 series signal conditioners |
25,000Yen / 40,000Yen |
6Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal Output 1M3.5 screw terminal Output 2M3.5 screw terminal Mountable moduleAll input modules except MS3954 and MS3954HI can be installed. |
Chassis Mount Type
Rack
For 4ch
Chassis for the MS3954 signal conditioners |
25,000Yen / 40,000Yen |
6Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal OutputM3.5 screw terminal Mountable moduleOutput module |
Chassis Mount Type
Rack
For 8ch
Chassis for the MS3900 series signal conditioners |
30,000Yen / 45,000Yen |
6Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal Output 1M3.5 screw terminal Output 2M3.5 screw terminal Mountable moduleAll input modules except MS3954 and MS3954HI can be installed. |
Chassis Mount Type
Rack
For 8ch
Chassis for the MS3954 signal conditioners |
30,000Yen / 45,000Yen |
6Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal OutputM3.5 screw terminal Mountable moduleOutput module |
Chassis Mount Type
Rack
For 16ch
Chassis for the MS3900 series signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal Output 1M3.5 screw terminal Output 2M3.5 screw terminal Mountable moduleAll input modules except MS3954 and MS3954HI can be installed. |
Chassis Mount Type
Rack
For 16ch
Chassis for the MS3954 signal conditioners |
35,000Yen / 50,000Yen |
6Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal OutputM3.5 screw terminal Mountable moduleOutput module |