MS3700 SeriesMS3700DV
Plug-in Type
Voltage Divider
Plug-in Type
Voltage Divider
Converts high DC voltage signals into DC voltage signals. |
10,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Unnecessary |
Input+/-600V max. Output 1Value obtained by multiplying input voltage by division ratio |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~200V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
Fast-Response Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time50μs max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
45,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA, 1 to 5V, Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
Converts 4-wire RTD inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire RTD: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
55,000Yen / 66,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD: Pt 100Ω, JPt 100Ω,Pt 50Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time240ms max. |
Plug-in Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
35,000Yen / 45,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 10mV, 0 to 100mV, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner
(Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
32,000Yen / 42,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(11-27V DC Powered)
Converts DC current or voltage signals into commonly used DC signals. This model operates with 11 to 27V DC power supply. |
42,000Yen / 52,000Yen |
4Days
|
7Years |
-
RoHS10
|
11~27V DC |
Input4 to 20mA, 1 to 5V, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(High Output Load Model)
Converts DC current or voltage signals into commonly used DC signals. This model features connection of output load resistance up to 1KΩ. |
42,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output4 to 20mA, 0 to 20mA Response Time85ms max. |
Plug-in Type
Isolator
(I/O Limited)
Converts 1 to 5V or 4 to 20mA DC signals into isolated 1 to 5V or 4 to 20mA DC signals. |
28,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V Output4 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(24V AC Powered)
Converts DC current or voltage signals into commonly used DC signals. This model operates with 24V AC power supply. |
42,000Yen / 52,000Yen |
4Days
|
7Years |
-
RoHS10
|
24V AC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(I/O Switch-Selectable)
Built-in switches enable selection of input and output from either 1 to 5V or 4 to 20mA. |
50,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 24 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(Outputs 1&2 Separately Adjustable)
Converts DC current or voltage signals into commonly used DC signals. This model features separate adjustment of Output 1 and Output 2. |
48,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA,0 to 20mA, 1 to 5V, 0 to 5V, Output 24 to 20mA, 1 to 5V, Response Time85ms max. |
Plug-in Type
Alarm Setter with Isolated Dual Output
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 0 to 20mA, Output 1Two form C relay contact outputs Output 2Rated load of contact: Response Time150ms max. |
Plug-in Type
Digital Alarm Setter
(High Accuracy Model)
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1Two form C relay contact outputs Output 2Rated load of contact: Response Time150ms max. |
Plug-in Type
Digital Alarm Setter
(High Accuracy Model)
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1Two form C relay contact outputs; rated load of contact: 5A 125V AC, 5A 30V DC Output 2Two form C contact relay outputs; rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 5 to 400mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
70,000Yen / 80,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 0.8 to 10mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Distributor (with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. |
38,000Yen / 48,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Distributor for Level Gauges
A wide span adjustment range allows the module to be used for level gauges with different ranges. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time200ms max. |
Plug-in Type
Distributor with HART Communication
Powers a two-wire transmitter and converts its 4 to 20mA signals into 4 to 20mA signals. The module isolates bidirectional HART communication signals. |
45,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output4 to 20mA Response Time500ms max. |
Plug-in Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
48,000Yen / 58,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response TimeDependent on input frequency. |
Plug-in Type
Pulse Shaper
(Pulse Isolator)
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
30,000Yen / 40,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
40,000Yen / 50,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
4-Wire Potentiometer Transmitter
Detects changes in the resistance of four-wire potentiometers and converts them into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire potetiometer total resistance: 300Ω; input span: 50 to 200Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Potentiometer Transmitter
(Constant Current Model)
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. This model features providing constant current to the sensor. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Pulse Divider
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
50,000Yen / 60,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Pulse Divider
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputDry contact, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Square-Root Extractor
Extracts the square roots of DC current or voltage signals and converts them into commonly used DC signals. |
43,000Yen / 53,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time120ms max. |