MS3700 SeriesMS3700DV
Plug-in Type
Voltage Divider
Plug-in Type
Voltage Divider
-
RoHS6
|
7Years |
4Days
|
10,000Yen |
Converts high DC voltage signals into DC voltage signals. |
Input+/-600V max. Output 1Value obtained by multiplying input voltage by division ratio |
Plug-in Type
Thermocouple Temperature Transmitter
CE
RoHS6
|
7Years |
4Days
|
47,000Yen / 57,000Yen |
Converts thermocouple inputs into commonly used DC signals. |
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
Fast-Response Thermocouple Temperature Transmitter
-
-
|
7Years |
4Days
|
55,000Yen / 65,000Yen |
Converts thermocouple inputs into commonly used DC signals. This model features a fast response time of 500μs or less (0 to 90%). |
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time50μs max. |
Plug-in Type
RTD Temperature Transmitter
CE
RoHS6
|
7Years |
4Days
|
45,000Yen / 55,000Yen |
Converts RTD inputs into commonly used DC signals. |
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
-
RoHS6
|
7Years |
4Days
|
55,000Yen / 65,000Yen |
Converts 4-wire RTD inputs into commonly used DC signals. |
Input4-wire RTD: Pt 100Ω, JPt 100Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
-
RoHS6
|
7Years |
4Days
|
55,000Yen / 66,000Yen |
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time240ms max. |
Plug-in Type
Millivolt Isolator
CE
RoHS6
|
7Years |
4Days
|
35,000Yen / 45,000Yen |
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
Input0 to 10mV, 0 to 100mV, +/-10V, +/-10mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner (Isolator)
CE
RoHS6
|
7Years |
4Days
|
32,000Yen / 42,000Yen |
Converts DC current or voltage signals into commonly used DC signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (11-27V DC Powered)
-
RoHS6
|
7Years |
4Days
|
42,000Yen / 52,000Yen |
Converts DC current or voltage signals into commonly used DC signals. This model operates with 11 to 27V DC power supply. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (High Output Load Model)
-
RoHS6
|
7Years |
4Days
|
42,000Yen |
Converts DC current or voltage signals into commonly used DC signals. This model features connection of output load resistance up to 1KΩ. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 0 to 20mA Response Time85ms max. |
Plug-in Type
Isolator (I/O Limited)
CE
RoHS6
|
7Years |
4Days
|
28,000Yen |
Converts 1 to 5V or 4 to 20mA DC signals into isolated 1 to 5V or 4 to 20mA DC signals. |
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 2Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (24V AC Powered)
-
RoHS6
|
7Years |
4Days
|
42,000Yen / 52,000Yen |
Converts DC current or voltage signals into commonly used DC signals. This model operates with 24V AC power supply. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (I/O Switch-Selectable)
CE
RoHS6
|
7Years |
4Days
|
50,000Yen |
Built-in switches enable selection of input and output from either 1 to 5V or 4 to 20mA. |
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 24 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner (Outputs 1&2 Separately Adjustable)
-
RoHS6
|
7Years |
4Days
|
48,000Yen |
Converts DC current or voltage signals into commonly used DC signals. This model features separate adjustment of Output 1 and Output 2. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Alarm Setter with Isolated Dual Output
CE
-
|
7Years |
4Days
|
55,000Yen |
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs Output 2Rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Digital Alarm Setter (High Accuracy Model)
-
RoHS6
|
7Years |
4Days
|
60,000Yen |
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs Output 2Rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Digital Alarm Setter (High Accuracy Model)
-
RoHS6
|
7Years |
4Days
|
60,000Yen |
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Two form C relay contact outputs; rated load of contact: 5A 125V AC, 5A 30V DC Output 2Two form C contact relay outputs; rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Strain Gauge Transmitter
-
-
|
7Years |
4Days
|
60,000Yen / 70,000Yen |
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Strain Gauge Transmitter
-
-
|
7Years |
4Days
|
70,000Yen / 80,000Yen |
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
InputSpan: 0.8 to 10mV; input range: -5 to 5mV; excitation voltage: 5V, 10V DC Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Distributor (with Isolation)
CE
RoHS6
|
7Years |
4Days
|
38,000Yen / 48,000Yen |
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Plug-in Type
Distributor for Level Gauges
-
RoHS6
|
7Years |
4Days
|
55,000Yen / 65,000Yen |
A wide span adjustment range allows the module to be used for level gauges with different ranges. |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time200ms max. |
Plug-in Type
Distributor with HART Communication
-
RoHS6
|
7Years |
4Days
|
45,000Yen |
Powers a two-wire transmitter and converts its 4 to 20mA signals into 4 to 20mA signals. The module isolates bidirectional HART communication signals. |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA Response Time500ms max. |
Plug-in Type
Frequency/Analog Converter
-
RoHS6
|
7Years |
4Days
|
48,000Yen / 58,000Yen |
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
InputOpen collector, DC voltage pulse, current pulse, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeDependent on input frequency. |
Plug-in Type
Pulse Shaper (Pulse Isolator)
-
RoHS6
|
7Years |
4Days
|
30,000Yen / 40,000Yen |
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
InputOpen collector, DC voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
CE
RoHS6
|
7Years |
4Days
|
40,000Yen / 50,000Yen |
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
4-Wire Potentiometer Transmitter
-
RoHS6
|
7Years |
4Days
|
47,000Yen / 57,000Yen |
Detects changes in the resistance of four-wire potentiometers and converts them into commonly used DC signals. |
Input4-wire potetiometer total resistance: 300Ω; input span: 50 to 200Ω Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Potentiometer Transmitter (Constant Current Model)
-
RoHS6
|
7Years |
4Days
|
47,000Yen / 57,000Yen |
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. This model features providing constant current to the sensor. |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Plug-in Type
Pulse Divider
-
-
|
7Years |
4Days
|
50,000Yen / 60,000Yen |
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
InputOpen collector, DC voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Pulse Divider
-
-
|
7Years |
4Days
|
60,000Yen / 70,000Yen |
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
InputDry contact, open collector, voltage pulse, current pulse, and others Output 1TTL level, open collector, voltage pulse Output 2TTL level, open collector, voltage pulse Response TimeDependent on input frequency. |
Plug-in Type
Square-Root Extractor
-
RoHS6
|
7Years |
4Days
|
43,000Yen / 53,000Yen |
Extracts the square roots of DC current or voltage signals and converts them into commonly used DC signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time120ms max. |