MS4900 SeriesMS4944
Rack Mount Type
High-Level Signal Conditioner (Fast Response Model)
Rack Mount Type
High-Level Signal Conditioner (Fast Response Model)
Converts DC current or voltage signals into commonly used DC signals. Fast response time: 80µs or less (0 to 90%) |
|
35,000Yen |
Please contact us
|
3Years |
-
RoHS10
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 10 to 100mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time80µsec |
Rack Mount Type
1U 19" Rack Chassis
Supplies external power to all signal conditioners via its internal backplane. |
|
115,000Yen |
Please contact us
|
3Years |
-
RoHS10
|
InputInput wiring: BNC connector Output 1Input wiring: BNC connector Output 2Mounted in 19" rack |
Rack Mount Type
Non-Conditioning I/O Adapter
I/O adapter used to connect to the output connectors for RC4000 without any signal conditioning. Successor model:MS4100-TB |
|
|
Please contact us
|
Please contact us |
-
-
|
|
Rack Mount Type
Thermocouple Temperature Transmitter
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides two mutually isolated DC output signals. Successor model: MS3701 or MS4101 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputThermocouple types: K, E, J, T, B, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two mutually isolated DC output signals. Successor model:MS3702 or MS4102 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Millivolt Isolator
Amplifies millivolt signals from sensors or other devices and converts them into two mutually isolated DC output signals. Successor model: MS3703 or MS4103 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputmV DC voltage (5 to 200mV DC span) Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
High-Level Signal Conditioner (Isolator)
Converts high-level DC input signals into two mutually isolated DC output signals. Successor model: MS3704 or MS4104 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Alarm Setter (Alarm Unit)
Compares the levels of DC current or voltage signals with two set-points and outputs two independent isolated relay contact closure signals. Successor model: MS3705 or MS4105 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 1Relay contacts Output 2Relay contacts Response TimeApprox. 3ms |
Rack Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like, amplifies the millivolt input signals, and converts them into two mutually isolated DC output signals. Successor model: MS3706 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. Successor model: MS3707 or MS4107 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Frequency/Analog Converter
Converts pulse train signals from flow meters and the like into two mutually isolated DC output signals. Successor model: MS3708 or MS4108 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeDependent on input frequency. |
Rack Mount Type
Pulse Shaper
Amplifies pulse input signals, shapes these pulses, and converts them into two mutually isolated pulse output signals. Successor model: MS3709 or MS4109 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 1TTL, open collector, voltage pulse Output 2TTL, open collector, voltage pulse |
Rack Mount Type
Potentiometer Transmitter
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. Successor model: MS3710 or MS4110 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Pulse Divider
Amplifies pulse input signals, shapes and divides these pulses, and converts them into two mutually isolated pulse output signals. Successor model: MS3711 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 1TTL, open collector, voltage pulse Output 2TTL, open collector, voltage pulse |
Rack Mount Type
Square-Root Extractor
Extracts the square roots of high-level DC input signals and converts them into two mutually isolated DC output signals. Successor model: MS3713 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V,and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
High-Level Signal Conditioner with Limiter
Converts DC current or voltage signals into commonly used DC signals and limits the outputs to force them to fall within the range between preset upper and lower limits. Successor model: MS3714 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
First-Order Delay Signal Conditioner
Converts high-level DC inputs into two mutually isolated first-order-delay DC outputs with an adjustable time constant between 0.2 and 20s. Successor model: MS3716 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time |
Rack Mount Type
2-Wire Transmitter with Square-Root Extraction Function
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. Successor model: MS3717 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Frequency/Analog Converter (for Ultra Low Frequency)
Converts slow pulse signals with extremely low frequency into two mutually isolated analog DC output signals. Successor model: MS3718 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeDependent on input range. |
Rack Mount Type
CT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. Successor model: MS3720 or MS4120 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 70ms (0 to 63%) |
Rack Mount Type
PT Transmitter (Rms Calculation)
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. Successor model: MS3721 or MS4121 |
|
|
Please contact us
|
Please contact us |
-
-
|
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 70ms (0 to 63%) |
Rack Mount Type
Electromotive Force Generator
Accepts standard process signals and provides millivolt signals proportional to the electromotive force of the thermocouple specified. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1Thermocouple types: K. E, J, T, B, and others Output 2None Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Current Sinker
Accepts standard process signal and provides a 4 to 20mA current loop output using externally applied voltage. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA; sinking output Output 2None Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Pneumatic-Electric Converter
Measures a pneumatic signal with a semiconductor pressure transducer and converts it into DC output signals. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input19.6 to 98.1KPa, 19.6 to 176.6KPa, 20 to 100KPa, 3 to 27psiG, 3 to 15psiG, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 24 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 200ms (0 to 99%) |
Rack Mount Type
AC Power Supply Unit
Accepts commercial AC power and provides 24V DC power for the MS4000 series signal conditioners. Successor model: PS4100-A |
|
|
Please contact us
|
Please contact us |
-
-
|
Input100V AC, 110V AC, 115V AC, 200V AC, 220V AC, 240V AC Output 124V DC |
Rack Mount Type
Rack
Rack for the MS4000 series signal conditioners. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
|
Rack Mount Type
Rack
Rack for the MS4000 series signal conditioners. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
|
Rack Mount Type
Rack
Rack for the MS4000 series signal conditioners. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
|
Rack Mount Type
Rack
Rack for the MS4000 series signal conditioners. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
|
Rack Mount Type
I/O Cable
Cable assembly for the RC4000 I/O connectors. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
|