MS5000 SeriesMS5000TH
Unit Type
Non-Conditioning I/O Adapter
Unit Type
Non-Conditioning I/O Adapter
-
RoHS6
|
7Years |
Please contact us
|
15,000Yen |
I/O adapter that does not provide any signal conditioning. Units can be ordered with a single or dual circuit, with or without a shunt resistor (250Ω), and with or without an input selector. |
InputOutput 1Dependent on input signal and input resistance. |
Unit Type
Thermocouple Temperature Transmitter
-
RoHS6
|
7Years |
Please contact us
|
30,000Yen |
Converts thermocouple inputs into commonly used DC signals. |
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Unit Type
Millivolt Isolator
-
RoHS6
|
7Years |
Please contact us
|
30,000Yen |
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
Input0 to 10mV, 0 to 100mV, +/-10mV, +/-100mV, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time160ms max. |
Unit Type
High-Level Signal Conditioner
-
RoHS6
|
7Years |
Please contact us
|
25,000Yen |
Converts DC current or voltage signals into commonly used DC signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max. |
Unit Type
Distributor
-
RoHS6
|
7Years |
Please contact us
|
22,000Yen |
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time85ms max./150µs max. |
Unit Type
RTD Temperature Transmitter
-
RoHS6
|
7Years |
Please contact us
|
30,000Yen |
Converts RTD inputs into commonly used DC signals. |
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response Time170ms max. |
Unit Type
4-Channel Isolator
-
-
|
1Years |
Please contact us
|
120,000Yen |
4-channel I/O isolator, providing full isolation between inputs, outputs, input and output, and I/O and power. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others |
|
Unit Type
4-Channel Isolator
-
-
|
1Years |
Please contact us
|
120,000Yen |
4-channel I/O isolator, providing full isolation between inputs, outputs, input and output, and I/O and power. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others |
|
Unit Type
Isolator
-
-
|
Please contact us |
Please contact us
|
150,000Yen |
High power isolator providing a maximum output of +/-10V (output load of +/-300mA) |
Input0 to 10V, 0 to 5V, +/-10V, +/-5V Output 10 to 10V, 0 to 5V, +/-10V, +/-5V Response Time1s max. |
|
Unit Type
Switch Box
-
RoHS6
|
Please contact us |
Please contact us
|
45,000Yen / 90,000Yen |
Switch box with a power fuse |
InputNumber of channels: 5 or 10 Output 1Fuse rating: 0.5A, 1.3A, 2.0A, 3.0A |
|
Unit Type
Thermocouple Temperature Transmitter
-
-
|
3Years |
45Days
|
62,000Yen |
Accepts millivolt signals from a thermocouple, performs cold junction compensation, amplification and linearization, and provides DC output signals. |
InputThermocouple types: K, E, J, T, B, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
RTD Temperature Transmitter
-
-
|
3Years |
45Days
|
61,000Yen |
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. |
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
Millivolt Isolator
-
-
|
3Years |
45Days
|
58,000Yen |
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
InputmV DC voltage (3 to 200mV DC span) Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
High-Level Signal Conditioner (Isolator)
-
-
|
3Years |
45Days
|
53,000Yen |
Converts high-level DC input signals into DC output signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
High-Level Signal Conditioner (Isolator) with Isolated Dual Output
-
-
|
3Years |
45Days
|
73,000Yen |
Converts high-level DC input signals into two mutually isolated DC output signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
Alarm Setter (Alarm Unit)
-
-
|
3Years |
45Days
|
58,000Yen |
Compares the levels of DC current or voltage signals with two set-points and outputs two independent isolated relay contact closure signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 1Relay contacts Output 2Relay contacts Response TimeApprox. 3ms |
|
Unit Type
Distributor
-
-
|
3Years |
45Days
|
63,000Yen |
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. |
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
Distributor with Isolated Dual Output
-
-
|
3Years |
45Days
|
83,000Yen |
Powers a two-wire transmitter and converts its 4 to 20mA signals into two mutually isolated DC output signals. |
Input4 to 20mA Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
Frequency/Analog Converter
-
-
|
3Years |
45Days
|
58,000Yen |
Converts pulse train signals from flow meters and the like into commonly used DC signals. |
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeDependent on input frequency. |
|
Unit Type
Pulse Shaper
-
-
|
3Years |
45Days
|
58,000Yen |
Amplifies pulse input signals, shapes these pulses, and converts them into two mutually isolated pulse output signals. |
InputDry contact, open collector, DC voltage pulse, AC voltage pulse Output 1TTL, open collector, voltage pulse |
|
Unit Type
Potentiometer Transmitter
-
-
|
3Years |
45Days
|
61,000Yen |
Supplies constant current to potentiometric sensors, amplifies the millivolt signals, and converts them into two mutually isolated DC output signals. |
InputSpecify between 0-100Ω and 0-10kΩ from 3-wire potentiometer. Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
Square-Root Extractor
-
-
|
3Years |
45Days
|
63,000Yen |
Extracts the square roots of high-level DC input signals and converts them into two mutually isolated DC output signals. |
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
CT Transmitter (Rms Calculation)
-
-
|
3Years |
45Days
|
55,000Yen |
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
Input0 to 1A AC, 0 to 5A AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |
|
Unit Type
PT Transmitter (Rms Calculation)
-
-
|
3Years |
45Days
|
55,000Yen |
Measures the supply voltage of power equipment and converts it into two mutually isolated DC output signals. |
Input0 to 110V AC, 0 to 150V AC, 0 to 300V AC, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 40ms (0 to 63%) |
|
Unit Type
RTD Differential Temperature Transmitter
-
-
|
3Years |
45Days
|
61,000Yen |
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. |
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
High-Level Signal Conditioner (High Voltage Output Model)
-
-
|
3Years |
45Days
|
63,000Yen |
Converts high-level DC input signals into extremely high voltage signals (+/-15V DC). |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1+/-15V Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
|
Unit Type
High-Level Signal Conditioner (Wideband & High Withstand Strength)
-
-
|
3Years |
45Days
|
63,000Yen |
Converts high-level DC input signals into DC output signals. This model supports wideband signals and has high dielectric strength. |
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 11 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 10Hz-3dB |
|
Unit Type
Pneumatic-Electric Converter
-
-
|
3Years |
45Days
|
73,000Yen |
Measures a pneumatic signal with a semiconductor pressure transducer and converts it into DC output signals. |
Input19.6 to 98.1KPa, 19.6 to 176.6KPa, 20 to 100KPa, 3 to 27psiG, 3 to 15psiG, and others Output 14 to 20mA, 1 to 5V, and others Response TimeApprox. 100ms (0 to 99%) |
|
Unit Type
2-Wire Pneumatic-Electric Converter
-
-
|
3Years |
45Days
|
70,000Yen |
Measures a pneumatic signal with a semiconductor pressure transducer and converts it into 4 to 20mA output signals. |
Input19.6 to 98.1KPa, 19.6 to 176.6KPa, 20 to 100KPa, 3 to 27psiG, 3 to 15psiG, and others Output 14 to 20mA Response TimeApprox. 100ms (0 to 99%) |
|
Unit Type
Rack
-
-
|
3Years |
45Days
|
30,000Yen |
Rack for the MS3200 series signal conditioners |
|
|