MS3700 SeriesMS3706
Plug-in Type
Strain Gauge Transmitter








Plug-in Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 5 to 400mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
70,000Yen / 80,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 0.8 to 10mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
42,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
4-Wire Potentiometer Transmitter
|
Detects changes in the resistance of four-wire potentiometers and converts them into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire potetiometer total resistance: 300Ω; input span: 50 to 200Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Potentiometer Transmitter
(Constant Current Model)
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. This model features providing constant current to the sensor. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
54,000Yen / 67,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 1A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400mse max. |
Plug-in Type
Fast-Response CT Transmitter
Average value calculation type
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. This model features a fast response time of 20ms or less (0 to 90%). |
62,000Yen / 72,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 1A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time20ms max. |
Plug-in Type
CT Transmitter (Clamp-Type CT Input)
|
Calculates the rms values of AC current signals from a clamp-type CT and converts them into commonly used DC signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 5A AC, 0 to 50A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time450ms max. |
Plug-in Type
PT Transmitter (Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
54,000Yen / 67,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 110V, AC Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
64,900Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
70,400Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 1A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
PT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
64,900Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 110V AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
61,600Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 5 to 400mV; Output4 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
33,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
38,500Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 1A AC, Output4 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
PT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
38,500Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 110V AC, Output4 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
50,000Yen / 63,000Yen |
5Days
|
1Years |
-
RoHS10
|
100~240V AC 24V DC |
Inputpotetiometer total resistance: Between 0-100Ω and 0-10kΩ Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
60,000Yen |
5Days
|
1Years |
-
RoHS10
|
100~240V AC 24V DC |
Inputpotetiometer total resistance: Between 0-100Ω and 0-10kΩ Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Terminal Block Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
29,700Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
24V DC 12V DC |
InputBetween 0-100Ω and 0-10kΩ Output4 to 20mA 0 to 20mA Response Time170ms max. |
Terminal Block Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
33,000Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
24V DC 12V DC |
Input0 to 1A AC, Output4 to 20mA 0 to 20mA Response Time400ms max. |
Terminal Block Type
PT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
33,000Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
24V DC 12V DC |
Input0 to 110V AC, Output4 to 20mA 0 to 20mA Response Time400ms max. |
Terminal Block Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
35,200Yen |
5Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 110V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Terminal Block Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
38,500Yen |
5Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 110V DC |
Input0 to 1A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Terminal Block Type
PT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
38,500Yen |
5Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 110V DC |
Input0 to 110V AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Chassis Mount Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
38,500Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time180ms max. |
Chassis Mount Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
Chassis Mount Type
CT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
36,300Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 1A AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
Chassis Mount Type
PT Transmitter
(Rms Calculation)
|
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
36,300Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 100V AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
Plug-in Type
DC Potentiometer Transmitter
|
Converts DC voltage or current signals into resistance values. |
|
140,000Yen |
Please contact us
|
3Years |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Output 1100ohm, 200ohm, 500ohm, 1kohm, 10kohm, 50kohm, and others Response TimeApprox. 5s (0 to 100%) |
Chassis Mount Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
38,500Yen |
6Days
|
3Years |
-
-
|
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 11 to 5V Output 24 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |


