Search by Application
Refuse Disposal Plant : Incinerator monitoring and control system
SEARCH
RESULTS
- Isolated Signal Conditioner:Temperature Transmitters:Thermocouple Temperature Transmitters
-
MS3900 SeriesMS3901
Chassis Mount Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
38,500Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC24V Supplied from a dedicated base |
InputThermocouple types: Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time160ms max. |
- Isolated Signal Conditioner:Temperature Transmitters:RTD Temperature Transmitters
-
MS3900 SeriesMS3902
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
InputRTD:Pt 100Ω、JPt 100Ω Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Conditioners (Isolators)
-
MS3900 SeriesMS3904
Chassis Mount Type
High-Level Signal Conditioner
(Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
22,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA, 1 to 5V, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time85ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:Strain Gauge Transmitters
-
MS3900 SeriesMS3906
Chassis Mount Type
Strain Gauge Transmitter
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
38,500Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputSpan: 5 to 400mV; input range: -200 to 200mV; excitation voltage: 5V DC, and others Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time180ms max. |
- Isolated Signal Conditioner:Distributors:Distributors
-
MS3900 SeriesMS3907
Chassis Mount Type
Distributor
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
27,500Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA from 2-wire transmitters Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time85ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:Potentiometer Transmitters
-
MS3900 SeriesMS3910
Chassis Mount Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
33,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
InputBetween 0-100Ω and 0-10kΩ Output 11 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:CT Transmitters
-
MS3900 SeriesMS3920
Chassis Mount Type
CT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
36,300Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 1A AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
- Isolated Signal Conditioner:Sensor Signal Conditioners:PT Transmitters
-
MS3900 SeriesMS3921
Chassis Mount Type
PT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
36,300Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input0 to 100V AC, Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time400ms max. |
- Isolated Signal Conditioner:High-level Signal Conditioners:High-level Signal Output Modules
-
MS3900 SeriesMS3954
Chassis Mount Type
High-Level Signal Conditioner
Converts DC current or voltage signals into commonly used DC signals. |
22,000Yen |
6Days
|
7Years |
-
RoHS10
|
DC 24V Supplied from a dedicated base |
Input4 to 20mA 0 to 20mA Output1 to 5V, 0 to 5V, Response Time15ms max. |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AI
Chassis Mount Type
Rack
For 16ch
Chassis for the MS3900 series signal conditioners |
38,500Yen / 55,000Yen |
6Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal Output 1M3.5 screw terminal Output 2M3.5 screw terminal Mountable moduleAll input modules except MS3954 and MS3954HI can be installed. |
- Isolated Signal Conditioner:Chassis:Chassis for MS3900
-
MS3900 SeriesRC3900A-16AO
Chassis Mount Type
Rack
For 16ch
Chassis for the MS3954 signal conditioners |
38,500Yen / 55,000Yen |
6Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC |
InputM3.5 screw terminal OutputM3.5 screw terminal Mountable moduleOutput module |
- Overview
- Download
- Price
- Standard Lead Time
- Warranty Period
- Standards & Approvals / RoHS
- Power Supply
- Details
- Basic Information
- Compare