MS3700 SeriesMS3700DV
Plug-in Type
Voltage Divider








Plug-in Type
Voltage Divider
|
Converts high DC voltage signals into DC voltage signals. |
10,000Yen |
4Days
|
7Years |
CE
RoHS10
|
Unnecessary |
Input+/-600V max. Output 1Value obtained by multiplying input voltage by division ratio |
Plug-in Type
Thermocouple Temperature Transmitter
|
Converts thermocouple inputs into commonly used DC signals. |
48,000Yen / 61,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~200V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
Fast-Response Thermocouple Temperature Transmitter
|
Converts thermocouple inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time50μs max. |
Plug-in Type
RTD Temperature Transmitter
|
Converts RTD inputs into commonly used DC signals. |
46,000Yen / 59,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA, 1 to 5V, Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
|
Converts 4-wire RTD inputs into commonly used DC signals. |
57,000Yen / 67,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire RTD: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
|
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
57,000Yen / 68,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD: Pt 100Ω, JPt 100Ω,Pt 50Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time240ms max. |
Plug-in Type
Millivolt Isolator
|
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
35,000Yen / 47,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 10mV, 0 to 100mV, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner
(Isolator)
|
Converts DC current or voltage signals into commonly used DC signals. |
34,000Yen / 47,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(11-27V DC Powered)
|
Converts DC current or voltage signals into commonly used DC signals. This model operates with 11 to 27V DC power supply. |
44,000Yen / 55,000Yen |
4Days
|
7Years |
-
RoHS10
|
11~27V DC |
Input4 to 20mA, 1 to 5V, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(High Output Load Model)
|
Converts DC current or voltage signals into commonly used DC signals. This model features connection of output load resistance up to 1KΩ. |
44,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output4 to 20mA, 0 to 20mA Response Time85ms max. |
Plug-in Type
Isolator
(I/O Limited)
|
Converts 1 to 5V or 4 to 20mA DC signals into isolated 1 to 5V or 4 to 20mA DC signals. |
28,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V Output4 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(24V AC Powered)
|
Converts DC current or voltage signals into commonly used DC signals. This model operates with 24V AC power supply. |
42,000Yen / 52,000Yen |
4Days
|
7Years |
-
RoHS10
|
24V AC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(I/O Switch-Selectable)
|
Built-in switches enable selection of input and output from either 1 to 5V or 4 to 20mA. |
50,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V Output 14 to 20mA, 1 to 5V Output 24 to 20mA, 1 to 5V Response Time85ms max. |
Plug-in Type
High-Level Signal Conditioner
(Outputs 1&2 Separately Adjustable)
|
Converts DC current or voltage signals into commonly used DC signals. This model features separate adjustment of Output 1 and Output 2. |
50,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA,0 to 20mA, 1 to 5V, 0 to 5V, Output 24 to 20mA, 1 to 5V, Response Time85ms max. |
Plug-in Type
Alarm Setter with Isolated Dual Output
|
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 0 to 20mA, Output 1Two form C relay contact outputs Output 2Rated load of contact: Response Time150ms max. |
Plug-in Type
Digital Alarm Setter
(High Accuracy Model)
|
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1Two form C relay contact outputs Output 2Rated load of contact: Response Time150ms max. |
Plug-in Type
Digital Alarm Setter
(High Accuracy Model)
|
Compares the levels of DC current or voltage signals with two set-points (upper and lower limits) and outputs two independent isolated relay contact closure signals. |
60,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1Two form C relay contact outputs; rated load of contact: 5A 125V AC, 5A 30V DC Output 2Two form C contact relay outputs; rated load of contact: 5A 125V AC, 5A 30V DC Response Time150ms max. |
Plug-in Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 5 to 400mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Strain Gauge Transmitter
|
Supplies excitation voltage to strain-gauge type pressure sensors, load cells and the like and converts their output signals into commonly used DC signals. |
70,000Yen / 80,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputSpan: 0.8 to 10mV; Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Distributor (with Isolation)
|
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. |
39,000Yen / 52,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters (Transmitter power supply: 24V DC) Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Distributor for Level Gauges
|
A wide span adjustment range allows the module to be used for level gauges with different ranges. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time200ms max. |
Plug-in Type
Distributor with HART Communication
|
Powers a two-wire transmitter and converts its 4 to 20mA signals into 4 to 20mA signals. The module isolates bidirectional HART communication signals. |
45,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output4 to 20mA Response Time500ms max. |
Plug-in Type
Frequency/Analog Converter
|
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
49,000Yen / 62,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response TimeDependent on input frequency. |
Plug-in Type
Pulse Shaper
(Pulse Isolator)
|
Accepts pulse train signals from sensors or other devices and shapes these pulses or converts signal levels as necessary. |
30,000Yen / 42,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
42,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
4-Wire Potentiometer Transmitter
|
Detects changes in the resistance of four-wire potentiometers and converts them into commonly used DC signals. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire potetiometer total resistance: 300Ω; input span: 50 to 200Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Potentiometer Transmitter
(Constant Current Model)
|
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. This model features providing constant current to the sensor. |
47,000Yen / 57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Pulse Divider
|
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
50,000Yen / 62,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Pulse Divider
|
Accepts pulse train signals from sensors or other devices, shapes or divides these pulses, and converts signal levels as necessary. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputDry contact, Output 1TTL level, Output 2TTL level, Response TimeDependent on input frequency. |
Plug-in Type
Square-Root Extractor
|
Extracts the square roots of DC current or voltage signals and converts them into commonly used DC signals. |
43,000Yen / 55,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time120ms max. |