MS3700 SeriesMS3702
Plug-in Type
RTD Temperature Transmitter
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
45,000Yen / 55,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA, 1 to 5V, Response Time170ms max. |
Plug-in Type
4-Wire RTD Temperature Transmitter
Converts 4-wire RTD inputs into commonly used DC signals. |
55,000Yen / 65,000Yen |
4Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4-wire RTD: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter (for Narrow Temperature Spans)
Converts RTD inputs into commonly used DC signals. This model is intended for measurement of narrow temperature spans (e.g. Pt100Ω input span of 30 to 50°C) |
55,000Yen / 66,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD: Pt 100Ω, JPt 100Ω,Pt 50Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time240ms max. |
Plug-in Type
RTD Differential Temperature Transmitter
Detects a temperature difference between two 2-wire RTD's and converts it into commonly used DC signals. |
64,000Yen / 74,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input2-wire RTD: x2 Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time200ms max. |
Plug-in Type
RTD Differential Temperature Transmitter
Detects a temperature difference between two 2-wire RTD's and converts it into commonly used DC signals. |
74,000Yen / 84,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input2-wire RTD: Pt100Ω -20 to 30°C, 0 to 50°C, 50 to 100°C, and others Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time150ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
89,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
38,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output4 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
55,000Yen / 68,000Yen |
5Days
|
1Years |
-
RoHS10
|
100~240V AC 24V DC ※For communication function, only AC power supply is available. |
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Response Time500ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
65,000Yen |
5Days
|
1Years |
-
RoHS10
|
100~240V AC |
InputPt 100Ω、JPt 100Ω Output 14~20mA 1~5V Output 24~20mA 1~5V Response Time500ms max. |
Terminal Block Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
29,000Yen |
5Days
|
7Years |
CE*
* Except 12V DC RoHS10
|
24V DC 12V DC |
InputRTD: Output4 to 20mA 0 to 20mA Response Time170ms max. |
Terminal Block Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
34,000Yen |
5Days
|
7Years |
CE
RoHS10
|
100~240V AC 24V DC 110V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
7Years |
CE*
* Some variants are not CE compliant. RoHS10
|
DC 24V Supplied from a dedicated base |
InputRTD:Pt 100Ω、JPt 100Ω Output 11 to 5V, 0 to 5V, Output 21 to 5V, 0 to 5V, Response Time170ms max. |
Unit Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
Please contact us
|
7Years |
-
RoHS10
|
24V DC |
InputRTD:Pt 100Ω、JPt 100Ω Output4 to 20mA 0 to 20mA Response Time170ms max. |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
30,000Yen |
6Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 5V, 0 to 10V Output 21 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
30,000Yen |
14Days
|
7Years |
-
RoHS10
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11~5V Response Time200ms max. |
Rack Mount Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two mutually isolated DC output signals. Successor model:MS3702 or MS4102 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Output 21 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two mutually isolated DC output signals. |
|
48,000Yen / 68,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Output 21 to 5V, 0 to 10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
2-Wire RTD Temperature Transmitter
Supplies constant current to 3-wire RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides two-wire DC current signals (4 to 20mA) for standard DC drive. |
|
|
Please contact us
|
Please contact us |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Chassis Mount Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
|
|
Please contact us
|
Please contact us |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 5V, 0 to 10V, 4 to 20mA Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Unit Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. |
|
61,000Yen |
45Days
|
3Years |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 1 to 5V, 0 to 10V, +/-10V, 0 to 5V, 0 to 1V, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
RTD Temperature Transmitter
Supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. Successor model:MS3702 or MS4102 |
|
|
Please contact us
|
Please contact us |
-
-
|
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Rack Mount Type
Non-Isolated RTD Temperature Transmitter
The MS2312 is a non-isolated RTD temperature transmitter that supplies constant current to RTD, performs cold junction compensation, amplification and linearization of its millivolt input signals, and provides DC output signals. No successor model. |
|
|
Please contact us
|
Please contact us |
-
-
|
Input4 to 20mA, 1 to 5V, 0 to 10V, 0 to 5V, and others Output 11 to 5V, 0 to 1V, 0 to 5V, 0 to 10V, 4 to 20mA, and others Response TimeApprox. 2Hz-3dB (63%: 0.1s) |
Plug-in Type
RTD Temperature Transmitter
Successor model: MS5302 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
RTD Temperature Transmitter
Successor model: MS5502 |
|
|
Please contact us
|
3Years |
-
-
|
|
Plug-in Type
4-Wire RTD Temperature Transmitter
Suggested replacement model: MS3702-01 (Similar specifications are available.) |
|
|
Please contact us
|
3Years |
-
-
|
|