MS3700 SeriesMS3764
Plug-in Type
Loop-Powered Isolator (2-Channel Model)
Plug-in Type
Loop-Powered Isolator (2-Channel Model)
Dual-channel loop-powered isolator that takes the power from its input current loop. |
38,000Yen |
4Days
|
7Years |
-
RoHS10
|
Unnecessary |
Input1 ch/2 ch: 4 to 20mA/4 to 20mA Output 11ch/2ch: 4 to 20mA/4 to 20mA, 1 to 5V/1 to 5V Output 21ch/2ch: 4 to 20mA/4 to 20mA, 1 to 5V/1 to 5V Response Time15ms |
Plug-in Type
Arithmetic Operation Unit
Receives two DC current or voltage signals and outputs a signal proportional to the result of an arithmetic operation (addition, subtraction, multiplication or division). |
65,000Yen / 75,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time150ms max. |
Plug-in Type
Analog Memory
Holds an output signal using external hold input. |
47,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output4 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Analog Memory
(Multi-Function Model)
Holds an output signal using external hold input. |
57,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output4 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Temperature/Pressure Compensator
Compensates for variations in temperature, pressure, or differential pressure for accurate flow calculation. |
150,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output4 to 20mA 0 to 20mA Response Time1s max. |
Plug-in Type
Programmable Linearizer
Accepts non-linear DC current or voltage input and provides linearized output. Up to 21 breakpoints can be configured for segment approximation. These breakpoints and I/O ranges can be changed using a PC. |
48,000Yen / 58,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputDC current input span: 1 to 50mA; Output 14 to 20mA, 0 to 10V, Output 2Output 1/Output 2: 1-5V/1-5V, 0-5V/0-5V, 0-10V/0-10V, 4-20mA/1-5V, 4-20mA/4-20mA Response Time1s max. |
Plug-in Type
Absolute Value Signal Conditioner
Converts DC current or voltage signals with polarity into absolute value signals. |
60,000Yen / 70,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputABS 0 to 20mA, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Split-Range Transmitter
Amplifies DC current or voltage input signals, converts them into split range control signals, and provides isolated dual output. Available in two output variants: V-shaped and parallel characteristics. |
50,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V, Output 14 to 20mA, 1 to 5V, Response Time500ms max. |
Plug-in Type
Programmable Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. PC programmable for I/O configuration. |
54,000Yen / 66,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA, 0 to 10V, Output 2Output 1/Output 2: 1-5V/1-5V, 0-5V/0-5V, 0-10V/0-10V, 4-20mA/1-5V, 4-20mA/4-20mA Response Time260ms max. |
Plug-in Type
Programmable RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. PC programmable for I/O configuration. |
54,000Yen / 64,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputRTD: Pt 100Ω, JPt 100Ω, Ni 508.4Ω, and others Output 14 to 20mA, 0 to 10V, 0 to 5V, 0 to 1V Output 2Output 1/Output 2: 1-5V/1-5V, 0-5V/0-5V, 0-10V/0-10V, 4-20mA/1-5V, 4-20mA/4-20mA Response Time260ms max. |
Plug-in Type
Programmable Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
48,000Yen / 64,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputInput span: 5mV to 2V Output 14 to 20mA, 0 to 10V, 0 to 5V, 0 to 1V Output 2Output 1/Output 2: 1-5V/1-5V, 0-5V/0-5V, 0-10V/0-10V, 4-20mA/1-5V, 4-20mA/4-20mA Response Time260ms max. |
Plug-in Type
Accumulator
Accumulator that converts DC current or voltage signals into pulse train signals. |
62,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1TTL level, Output 2Relay contacts: Form A contacts |
Plug-in Type
PWM Converter
Converts DC current or voltage signals into PWM signals. |
57,000Yen / 67,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 1TTL level, Output 2TTL level, Response Time1s max. |
Plug-in Type
High-Level Signal Conditioner
(High Current Output Model)
Converts DC current or voltage signals into high DC current signals. |
180,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA, 1 to 5V, OutputSpecify within the range of -320 to 320mA. Response Time160ms max. |
Plug-in Type
Socket
Socket for the MS3700 Series |
|
2,000Yen |
4Days
|
7Years |
-
RoHS10
|
|
Plug-in Type
Connecting Cable (for Programmable Models)
Connecting cable used for downloading configuration software for programmable signal conditioners |
|
15,000Yen |
4Days
|
7Years |
-
RoHS10
|
|
Plug-in Type
Precision resistor (250Ω, 50Ω)
Precision resistor (250Ω/50Ω) with lead wires. It is available in either fork or ring type terminal lugs for M3.5 screws. |
|
2,000Yen |
4Days
|
7Years |
-
RoHS10
|
|
Plug-in Type
|
64,000Yen / 74,000Yen |
4Days
|
3Years |
-
RoHS10
|
100~240V AC 24V DC 110 DC |
Out Put |
Plug-in Type
Thermocouple Temperature Transmitter
Converts thermocouple inputs into commonly used DC signals. |
97,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputThermocouple types: Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
RTD Temperature Transmitter
Converts RTD inputs into commonly used DC signals. |
89,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
Millivolt Isolator
Converts millivolt signals from sensors or other devices into commonly used DC signals. |
64,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 10mV, 0 to 100mV, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time160ms max. |
Plug-in Type
High-Level Signal Conditioner
(Isolator)
Converts DC current or voltage signals into commonly used DC signals. |
64,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA 0 to 20mA Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Digital Alarm Setter (Dual/Quad Outputs; with Indicators)
Compares the levels of DC current or voltage signals with two or four set-points and outputs two or four independent isolated relay contact closure signals. |
64,000Yen / 74,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 110 DC |
Input4 to 20mA 0 to 20mA OutputRelay contact outputs; form A contacts: 4 outputs, form B contacts: 4 outputs, form C contacts: 2 outputs Response Time500ms max. |
Plug-in Type
Distributor
(with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Distributor
(with Isolation)
Powers a two-wire transmitter and converts its 4 to 20mA signals into commonly used DC signals. This model can also be used as an isolator. |
65,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input4 to 20mA from 2-wire transmitters Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time85ms max. |
Plug-in Type
Frequency/Analog Converter
Converts pulse train signals from flow sensors and the like into commonly used DC signals. |
89,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputOpen collector, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response TimeDependent on input frequency. |
Plug-in Type
Potentiometer Transmitter
Detects changes in the resistance of potentiometric sensors and converts them into commonly used DC signals. |
59,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
InputBetween 0-100Ω and 0-10kΩ Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time170ms max. |
Plug-in Type
CT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a CT and converts them into commonly used DC signals. |
64,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 1A AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
PT Transmitter
(Rms Calculation)
Calculates the rms values of AC current signals from a PT and converts them into commonly used DC signals. |
59,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC 24V DC 100~240V DC |
Input0 to 110V AC, Output 14 to 20mA 0 to 20mA Output 24 to 20mA 0 to 20mA Response Time400ms max. |
Plug-in Type
Insulation Resistance Monitor
Continuously monitors the insulation resistance of an inactive motor and indicates the insulation status at three levels: GOOD, ALARM, and FAILURE. |
96,000Yen |
4Days
|
7Years |
-
RoHS10
|
100~240V AC |